Subject:  Some sort of booster pump needed...

Fertilizing and Watering      Return to Board List

From

Location

Message

Date Posted

Steve's Garage

New Castle, Indiana

So for next year I'm looking to run at least four impact sprinklers...maybe six. Right now, the water pressure I have coming from the sill cock spigot is just barely enough to run one...and sometimes it gets stuck with momentary loss of pressure.

So obviously I need a booster pump to run multiple, but I also wanted to run a timer system like the B-Hyve system. Thing is though....I assume the pump will continue to run even when the system isn't running, which would burn up the pump. There's no point in having a timer system if I have to be here anyway to turn the pump on and off.

So...is there a pump I can get that would shut off when the flow of water has stopped? Or even better, is there a timer system that also can shut off power to a pump when not in use?

8/22/2023 5:31:03 PM

Andy W

Western NY

Could you just plug the pump into a programmable electric timer?

8/22/2023 8:57:55 PM

pumpkinpal2

Syracuse, NY

Drummond 1 HP Sprinkler Pump.

Approximately $149 at Harbor Freight Tools. U can search for discounts.
I love my pump.
I dream of having a few of them when I upgrade to my new patch -
they'd still be in boxes for years, though, until my present one retires!

https://www.harborfreight.com/1-hp-portable-sprinkler-pump-1075-gph-63320.html

If not THIS pump due to cost, get one at least with the same specs;
Do not under-power your patch with a lesser pump!
Here is a picture of mine in all its glory but not a great picture but it has not failed me and
has always been overly-powerful for the money:

http://www.bigpumpkins.com/Diary/DiaryViewOne.asp?eid=340388

When the liquid you run is thicker than plain water, it seems to influence the pressure/flow
available at each of (MY) Whizzer sprinklers.

It is not a 'good-sounding' pump if it's not full of water during operation, but if and once
it IS in an airless system, like brakes on a car, she runs as any other.

65 PSI when closed off and although you're not supposed to do that,
I do it as a needed regimen, followed by orchestration of the limiter
shutoff valves I show in my Diary.
55-60 PSI, though, when actually running to any sprinkler.
They hold back the BEAST!

8/22/2023 9:44:05 PM

pumpkinpal2

Syracuse, NY

As with any pump, be CERTAIN that the hoses and fittings can handle
70+ PSI or at least be shielded away, just like mine aren't, lol.

*Once you have a 55-gallon barrel to incorporate, you can add ANYthing you want.
ANYthing...

I don't care if you don't use it butt I cannot say anything bad about it - That is a rarity!
I had 7 Whizzers running the other day and was perplexed by that #...then, my barrel ran out
and I was like 'Well, that'll teach ya!'.

I CAN run 3 Whizzers effectively, 2 amazingly and
ONE? ...is fearing for its life at a 40 feet in diameter circle.
***I have this running through about 1000 feet of hose to my FPs, including through
those damned 1/4-inch hose fittings and shutoffs. It works, though.***

I don't think it'll be a worry about a timer and your presence.
Others will chime in. Oh, there's one now - Hey, Andy!
I have the Yankee Kill Switch depicted in-Diary.

Since I'm here, any timer would simply have to have higher-than-needed ratings and be
firmly 'plugged in' to avoid any arcing at the outlet - like 'plugged in here'
and then the timer, then the pump.

I must mention that a sump pump switch was to be used in my system, but it has not yet
gelled. Within a barrel, there's your timer! I can explain that idea in the winter.

Oops - already done.
Later---eric g

8/22/2023 9:44:58 PM

don young

you will need timer that also has capability for pump relay
kind of complicated but I installed both this year

8/22/2023 10:33:44 PM

Steve's Garage

New Castle, Indiana

Ah yes pump relay! That's what I was looking for.

Eric, that one probably would suit my needs. There are numerous pumps I've seen that would work and I am trying to stay in the 120 volt range. If I get a timer with a pump controller and a pump relay I should be able to get it up the way I want. All my hoses are 100 psi.

8/23/2023 10:13:28 AM

pumpkinpal2

Syracuse, NY

Yay! Only Fall and Winter to get through, now! eg